Refrigerant Products
Refrigerant Heat Exchanger Suction Accumlators
Refrigerant Heat Exchanger Suction Accumlators

Refrigerant Heat Exchanger Suction Accumlators

PAT #M385679

Type Drawing Size Conn. O.D.S DIA  A Connections Size B C D H E F
IN OUT
RAH-304 a 1/2" 4" 3/8" 3/8" 8.58 0.98 1.57 4.72 1.89 1.57
RAH-305 b 5/8" 5.5" 3/8" 3/8" 10.35 1.38 2.08 5.91 2.17 1.89
RAH-307 b 7/8" 6.5" 3/8" 3/8" 12.72 1.38 3.15 7.09 2.17 1.89
RAH-307A C 7/8" 8.5 1/2" 1/2" 13.78 1.38 3.35 6.81 2.56 3.35
RAH-311 c 1 1/8" 8.5 1/2" 1/2" 13.78 1.38 3.55 6.81 2.56 3.35
RAH-313 c 1 3/8" 5/8" 5/8" 15.35 1.38 3.55 6.81 2.56 3.35  
RAH-315 c 1 5/8" 5/8" 5/8" 18.50 1.77 3.55 6.81 2.56 3.35  
RAH-321 d 2 1/8" 10.75" 7/8" 7/8" 21.85 2.36 4.72 7.83 4.53 5.51

 SIZE:INCH LICH:2.54CM  

Max . Permissible pressure:  31.03 bar , ( 450 psi )/-10°C~+150°C
20.67 bar , ( 300 psi )/-45°C~-10°C  
Unit : inch  

here are both high-tension and low-tension refrigerants in the air-conditioning system. The high-tension frigerant with higher temperature needs to be cooled through refrigeration Fand the low-tension refrigerant with wer temperature need to be sep-arated to liquid and gasified refrigerant by the separator Fand also, liquid frigerant needs time and temperature to evaporate and to be gasified before flowing into compressor to avoid quid compressed.

hte function exchanger is to gather the above mentioned refrigerants in one container, and to balance the mperature of both refrigerants under the principle of heat conduction. The dfficiency of whole system can hieve the best cooling effect through this reciprocal heat interaction.